SELECT-O-STOP
function is activated by the calibrated
switch actuator which is mounted on the side of the ram. Select-O-Stop
allows the operator to bring the ram down to a preset position
which is 1/4" above the material being formed and will automatically
stop the ram. this gives the operator the opportunity to realign
the work piece and then slow form the workpiece if desired. Select-O-Stop
is a keyed function on/off on the main control panel.
LIGHT GUARD
MUTE-OUT Automatically
by-passes light guard when die has reached piece part and point
of operation hazard no longer exists. Light guard is automatically
reactivated when press reaches top of stroke to prevent operator
from being in point of operation during the hazardous downstroke
of the press. Light guard mute out only is supplied when a light
curtain is used as the point of operation guarding device.
|