- Power Requirements: 120VAC +/- 10%
@ 50-60 Hz with fuse protection (24 VDC units optional).
- Power Consumption: 24 watts total
- Infrared Light Source: Solid state light
emitting diodes
- Beam Spacing: 3/4"(19mm);
1-1/2" (38mm) for Model TR-48 through TR-72
- Response Time: Less
than 30 milliseconds (All sizes)
- Relay Contact Ratings: 8 AMP rating @ 220VAC; 16 AMP rating
@ 120VAC
- Relay Configuration: Dual captive
contact self-checking safety relays.
- Minimum Object Sensitivity: 1-1/4"
(32mm); 2" (51mm) for Models TR-48 through TR-72.
- External Alpha-numeric Diagnostic
and Status Display
- Temperature Range: 32
degrees to 120 degrees F
- Scanning Frequency: 3.6 Khz
- Shock: Tested to withstand high vibration applications.
- Self-checking every 20 milliseconds.
- Indicators: Red obstruction light on detector. Green non-obstruction
light on detector. Red alignment indicator light on emitter.
- Construction: Heavy
duty aluminum enclosure (all welded). 14 Gauge - Dust and oil
tight. NEMA 12
- Scanning Distance: All units are
supplied standard with a 20' scanning capability. Extended range
units are available, consult your representative or the factory.
Scanning distances must be specified (75' maximum).
- Specials: Custom designed
light curtains for special applications. Examples: L-shaped,
stainless steel. Consult factory.
- CSA Approved, UL Pending
- Three-Year Warranty
|
|