  • Power Requirements: 120VAC +/- 10% @ 50-60 Hz with fuse protection (24 VDC units optional).
  • Power Consumption: 24 watts total
  • Infrared Light Source: Solid state light emitting diodes
  • Beam Spacing: 3/4"(19mm); 1-1/2" (38mm) for Model TR-48 through TR-72
  • Response Time: Less than 30 milliseconds (All sizes)
  • Relay Contact Ratings: 8 AMP rating @ 220VAC; 16 AMP rating @ 120VAC
  • Relay Configuration: Dual captive contact self-checking safety relays.
  • Minimum Object Sensitivity: 1-1/4" (32mm); 2" (51mm) for Models TR-48 through TR-72.
  • External Alpha-numeric Diagnostic and Status Display
  • Temperature Range: 32 degrees to 120 degrees F
  • Scanning Frequency: 3.6 Khz
  • Shock: Tested to withstand high vibration applications.
  • Self-checking every 20 milliseconds.
  • Indicators: Red obstruction light on detector. Green non-obstruction light on detector. Red alignment indicator light on emitter.
  • Construction: Heavy duty aluminum enclosure (all welded). 14 Gauge - Dust and oil tight. NEMA 12
  • Scanning Distance: All units are supplied standard with a 20' scanning capability. Extended range units are available, consult your representative or the factory. Scanning distances must be specified (75' maximum).
  • Specials: Custom designed light curtains for special applications. Examples: L-shaped, stainless steel. Consult factory.
  • CSA Approved, UL Pending